| Stored energy | 5632Wh |
| Rated capacity | 440Ah |
| Nominal voltage | 12.8V |
| Volt range | 10V-14.4V |
| Charge time | Standard 5h |
| Rapid 2.2h | |
| Charge method CC-CV | Standard 90A/14V |
| Rapid 200A/14V | |
| Max discharge current | Continous 200A |
| Cycle life 0.5C, 23℃/73°F | 50% >7000 cycles |
| 100% >2000 cycles | |
| Operating temperature range | Charge 0°C~45°C/32°F~113°F |
| Discharge -20°C~60°C/-4°F~140°F | |
| Storage(1month) -20°C~45°C/-4°F~113°F | |
| Storage(6month) -10°C~35°C/-4°F~95°F | |
| Water proof | IP67 |
| Self-consumption | Working ≤40mA |
| Hibernate ≤100μA | |
| Approx weight | 50kg /110.2lbs |
| Series & parallel connection | Max 8 batteries parallel connection. Series connection is not available. Batteries must be fully charge before parallel connection. |
| Length | Width | Width |
| 520mm | 268mm | 220mm |
| 20.5in | 10.6in | 8.7in |
| Balance | Current | 50mA |
| Activate volt | 3.55V/ cell | |
| Cell voltage difference | >20mV | |
| High temperature protection(MOSFET) | Protection | 115°C/239°F |
| Release | 90°C/194°F | |
| High temperature protection(cell) | Protection | 65°C/149°F(charge) |
| 70°C/158°F(discharge) | ||
| Release | 55°C/131°F(charge) | |
| 60°C/140°F(discharge) | ||
| Low temperature protection(cell) | Protection | -5°C/23°F(charge) |
| -20°C/-4°F(discharge) | ||
| Release | 0°C/32°F(charge) | |
| -15°C/5°F(discharge) | ||
| Charge Over-current | Protection | 250A @ 1S |
| Release | Wait for 60S or discharge current >1A. If charge over-current protection over 10 times, need re-start battery to release the protection. | |
| Discharge Over-current | Protection | 900A @ 1S |
| Release | Wait for 60S or charge current >1A. If discharge over-current protection over 10 times, need re-start battery to release the protection. | |
| Over-charge | Protection | 15.2V(3.8V/cell) |
| Release | 13.52V(3.38V/cell) | |
| or discharge current >1A | ||
| Over-discharge | Protection | 10V(2.5V/cell) |
| Release | 11.8V(2.8V/cell) | |
| Short-circuit | Protection | 1800A |
| Release | Remove load for the short circuit protection to release | |
| Length | Width | Width |
| 520mm | 268mm | 220mm |
| 20.5in | 10.6in | 8.7in |
Adopts FEVE anti-corrosion housing, 304 stainless steel terminals and IP67 waterproof rating. Passes 72-hour salt spray test, adapting to humid and corrosive marine and RV outdoor scenarios.
Real-time monitoring via Victron display/VRM/LILEAD display; full control over key parameters.
No downtime during replacement; maintains system stability; RS485 & CANBUS dual-protocol for wide compatibility.
Communicates with Victron system in real time to automatically adjust CCL and CVL parameters, optimizing battery safety and service life simultaneously.
Adjusts generator output via dry contact signal automatically. Unattended operation realizes intelligent marine energy allocation.
Reaction Time: 3 seconds to power off
Operation: System triggers → battery disconnects and shuts down
Benefit: Maximizes onboard electrical safety